Project Description
SELF REGULATING HEATING CABLES CABT/DE-ICING
The self regulating heating cable CABT/De-Icing is specily designed to prevent against the accumulation of snow or ice on roofs and gutters.
The innovative technology of the Technitrace self-regulating heating adpts its calorific output (W/m) at each point. In presence of snow or ice, its calorific output will increase locally to melt the snow or the ice.When the heating cable will be in a dry atmosphere it will reduce its calorific output saving energy.
MAIN APPLICATION
Self regulating heating cables CABT/De-icing
- Anti snow/ice self regulating heating cable for roofs  particularly for those with  gentle slopes.
- Anti snow/ice self regulating heating cable for gutters and connecting channels between the roof.
- Anti snow/ice self regulating heating cable for cloggeds drain pipes
- Prevent discharge pipes from freezing.
- snow removal of roofs and particularly at low slopes
- snow removal of gutters, connecting gutters between roofs
- snow removal of gutter runs and heaving pipes
- de-icing of the evacuation gutter, …
CONSTRUCTION OF A SELF REGULATING HEATING CABLE CABT/DE-INCING
INSTALLATION OF SELF REGULATING HEATING CABLE CABT/DE-ICING
GENERAL FEATURES
- Maximum lengtht : 110 m
- Max temperature exposure ON : 65°C
- Max temperature exposure OFF : 85°C
- Supply voltage  : 230 V / 50 Hz
- Breaker thermal protection : 0.30A/m
- Breaker sensibility : 30 mA advised
- Output calorific power: following the thermal transfer : 40 to 20W/m